E-Tech ET8 Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Systèmes de contrôle d'accès de sécurité E-Tech ET8. E-Tech ET8 Installation manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - A$12.00 INC GST

INSTALLATION & PROGRAMMING MANUALInstallation & Programming Manual - Click for HelpA$12.00 INC GSTE-TECH ET8 CONTROL PANEL V4 – INSTALLATION M

Page 2 - “Australia’s largest

10E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALKEYPADZone is sealedZone is unsealed, or Power faultor System is Armed,or phone line faultDisarmedDi

Page 3 - CONTENTS

11E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALOPERATION SUMMARYARMDISARMMONITOR MODEPANICKEYPAD DURESSEXCLUDING ZONESALARM MEMORYor...or...or...or

Page 4 - FEATURES

12PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALQUICK START PROGRAMMINGUse one of these programming summaries for fast setup of your ET8

Page 5 - SPECIFICATIONS

13PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL[INSTALLER CODE]Factory default Installer Code: 000000[MASTER CODE]Factory default Master

Page 6 - ZONE CONNECTION EXAMPLES

14PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALUSER CODESUser codes are the 3 to 6 digit codes used to operate the panel by keypad.User

Page 7 - E-Tech ET8

15PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALENTRY DELAY TIME1The Entry Delay Time 1 is the time given to Disarm the Panel after a Ent

Page 8

16PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALVIBRATION SENSITIVITYEach zone has individually adjustable sensitivity for connection of

Page 9

17PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALDOUBLE TRIGGER ZONESZones programmed to Double Trigger will recognise an alarm condition

Page 10 - KEYPAD BEEPER SOUNDS

18PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALHANDOVER ZONESHandover zones are delayed only if entry is made through an Entry Delay zon

Page 11 - OPERATION SUMMARY

19PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALDAY ZONESDay Zones operate when the panel is fully disarmed, i.e. when Area 1, Area 2and

Page 12 - QUICK START PROGRAMMING

HEAD OFFICE:E-Tech Security Products Pty LtdABN 000 110 11012 Security CloseSafe Hills NSW 2147 AustraliaPh +61 23 9988 7766Fax +61 23 9988 7765“Austr

Page 13 - PROGRAM light

20PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALDEFINITIONArea Partitioning allows the 8 zones to be split into twopartitions; Area1 and

Page 14 - P01E – P10E

21PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALP47E, P48EDESCRIPTION:Area 1 User CodesPROGRAM MODE LEVEL:Installer, Remote by PCFACTORY

Page 15

22PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALZONE TO OUTPUT MAPPINGWhen a zone alarms, it can turn on any or all of the following 6 ou

Page 16 - ON = Factory default setting

23PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALP57EPROGRAM MODE LEVEL:Installer, Remote by PCFACTORY DEFAULT:all ON: All zones trigger S

Page 17

24PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALENTRY BEEPSThe sonalert will beep during Entry Delay.PROGRAMMING SEQUENCE:P60E 1E toggles

Page 18

25PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALTAMPER ALARM LOCKOUTThis option programs the Tamper input to Lockout, i.e. cause the Sire

Page 19

26PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALTAMPER ALARM / OUTPUT MAPPINGThis option selects which outputs will trigger when a Tamper

Page 20 - P46E Area 2 zones

27PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALSYSTEM OPERATION SHORTCUTSSome keypad operations can be programmed to operate with or wit

Page 21 - P49E, P50E

28PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALMONITOR MODE OUTPUT MAPPINGThis option selects which outputs are triggered by alarms in M

Page 22

29PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL2 SECOND MONITOR MODE ALARMAlarms in Monitor Mode can either activate the programmed outp

Page 23

CONTENTSIntroduction ... 4Features ...

Page 24 - P60E 2E, 3E

30PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL50Hz MAINS FREQUENCYSelects either 50Hz or 60Hz mains power frequency operation. Leave th

Page 25

31PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALSUPERVISED RADIO ZONESThis option assigns zones that will operate as Radio Supervised typ

Page 26 - P61E 5E–8E

32PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALRADIO SUPERVISION ALERTS – RESET OUTPUTSetting this option turns the Reset output ON when

Page 27 - P62E 1E–6E

33PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALRADIO SUPERVISION ALERTS – SIREN OUTPUTSetting this option turns the Siren output ON when

Page 28 - P63E 5E–8E

34PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL3K3 ZONE RESISTORSSetting this option ON changes the Zone 1 to Zone 8 (and External Tampe

Page 29

35PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL24HR ZONE FIRE SIREN SOUNDThis option changes the siren sound when a 24hr zone is trigger

Page 30

36PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALARM1 PULSE OUTPUTThis option selects the ARM1 output to pulse on for 2 seconds wheneverar

Page 31 - P65E Supervised zonesRadio

37PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL6 BEEPS ON ARMINGNormally the keypad/s onboard SONALERT gives 3 beeps when the ET8 isArme

Page 32

38PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALTELEPHONE NUMBERS 1 & 2The ET8 can dial up to 2 phone numbers when an event is to be

Page 33

39PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALTELEPHONE NUMBER 3 – TEST CALLSPhone Number 3 is used to send Test Calls. If it is not pr

Page 34

4E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALThe E-TECH ET8 is a wholly Australian Designed and Manufactured productfrom E-Tech Security Products,

Page 35

40PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALREPORT ZONE ALARMSThis option selects which zone inputs will send Alarm reports to the Ce

Page 36

41PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALREPORT MISCELLANEOUS ALARMSREPORT MISCELLANEOUS RESTORALSThese options select which Misce

Page 37

42PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALTEST CALL INTERVALTest calls to the Central Station can be sent at intervals between 2 an

Page 38 - P72E, P73E

43PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL1E 2E 3E 4E 5E 6E 7E 8EON = Factory default setting.Disable diallerContact ID formatAudib

Page 39

44PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALCONTACT ID + AUDIBLE DTMF FORMATFor simultaneous Central Station and Audible Monitoring.T

Page 40

45PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL1E 2E 3E 4E 5E 6E 7E 8EON = Factory default setting.Split dial Phone Nos.Check for dial t

Page 41 - P82E 1E–4E

46PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL1E 2E 3E 4E 5E 6E 7E 8EON = Factory default setting.AREA1 Open/Close reportAREA2 Open/Clo

Page 42 - P85E 1E–3E

47PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALFORCED OPENING REPORTIf Forced Opening Report is selected ON – when an alarm has been res

Page 43

48PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL1E 2E 3E 4E 5E 6E 7E 8EON = Factory default setting.Enable Test CallsMains Report delayLi

Page 44

49PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALSWINGER SHUTDOWNLimits the number of calls made by a zone alarm when Multiple Zone Alarms

Page 45

5E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALINSTALLATION PROCEDURESThe location of the main panel housing should be in an area that is within the

Page 46

50PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL1E 2E 3E 4E 5E 6E 7E 8EON = Factory default setting.Upload/DownloadDirect ConnectRemote A

Page 47

51PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALCALLBACK MODEEnables two methods of connecting by computer for remote upload/download.NO

Page 48

52PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALREQUIRED RINGSSets the number of double-rings before an incoming call is answered. This i

Page 49

53PROGRAMMINGE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALCLEAR MEMORYEnter P96E when in Installer Program mode to clear all events in the Alarm me

Page 50

54E-TECH RADIOE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALRADIO QUICK STARTPROGRAMMING RADIO KEYS:Select which User Codes 2–8 will be Radio Codes

Page 51

55E-TECH RADIOE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALRADIO DEVICES – OPERATIONALARM: Any E-Tech Radio Device can operate on any zone 1–8 as p

Page 52

56E-TECH RADIOE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALRADIO DEVICE PROGRAMMINGEach of the 8 zones of the ET8 can be a radio zone. Once program

Page 53

57E-TECH RADIOE-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALRADIO CODESEach of the 15 User Codes, except for the Master Code, can be programmed tobe

Page 54 - SIGNAL STRENGTH

58E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALAUDIBLE MONITORINGWhile Central Station Monitoring is recommended, the ET8 can also sendaudible alar

Page 55 - E-TECH RADIO

59E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALOPERATING THE ET8 BY TELEPHONEThe ET8 will allow a user to call in tothe panel, using a standard DTM

Page 56 - RADIO DEVICE PROGRAMMING

6E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALCONNECTION DIAGRAMJ1J2RECEIVERPROGTAMPBATTERYE-TECH SECURITY PRODUCTS105-220TELEPHONEHEATSINKJ3AUX1AU

Page 57 - RADIO CODES

60E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALSWITCHESA variety of switches are available for protecting doors and windows.The line-up includes su

Page 58 - CENTRAL STATION MONITORING

61E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALWIRELESS PRODUCTSRADIO ACCESSORIESAsk your installer about the range of E-Tech radio devices for th

Page 59

62E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALP88EP89EP96EP97EP98EP91EP95EP90EP87EP85EP86EP83EP84EOPTION DESCRIPTION DEFAULT PAGE OPTION DESCRIPTI

Page 60 - E-TECH ACCESSORIES

63E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALDate purchased:INSTALLATION RECORDDate installed:Installation Company:Telephone:Monitoring Company:T

Page 62 - Report misc. ALARMS 9

7E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALE-Tech ET8CONTROLPANELE-Tech ET8CONTROLPANELE-Tech ET8CONTROLPANELE-Tech ET8CONTROLPANEL0VALARMTAMPER

Page 63 - INSTALLATION RECORD

8E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUALMONITORED ZONESThe E-Tech ET8 has 10 separate monitored inputs.• 8 x Fully programmable Zone inputs•

Page 64

9E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL12 VOLT OUTPUT:A regulated 13.8 VDC output is available to power detectors and otherequipment. This o

Commentaires sur ces manuels

Pas de commentaire