58
E-TECH ET8 (V4) CONTROL PANEL – INSTALLER MANUAL
AUDIBLE MONITORING
While Central Station Monitoring is recommended, the ET8 can also send
audible alarm reports to any DTMF capable telephone. The types of alarms
sent are listed in the Reporting Format Table.
The basic audible message takes the form of:
N [pause] A [pause] B [pause]
N = The first digit of the Account Number, P72E.
(N can be the digits 1–9. If P72E starts with 0, N is not sent).
A = First digit of the Alarm identifier (See Reporting Format Table).
B = Second digit of the Alarm identifier (See Reporting Format Table).
MESSAGE EXAMPLE (AUDIBLE PULSE FORMAT P86E 4E)
If the Account Number is 1234 and zone 5 alarm is reported:
beep beep beep beep beep beep[pause]
1 Beep
5 Beeps
= 1st digit of the
= zone 5
account number
REPORTING SEQUENCE
When triggered by an alarm event the ET8 will call the Primary Telephone
Number (or the Follow Me Telephone Number, if programmed) and at the end
of the dialling of the last digit, it will wait for 5 seconds and then commence the
audible message, the audible message will continue to repeat for 45 seconds
or until it is kissed off by a DTMF tone.
If there is more than one alarm message to transmit then after it has received
the Kiss-off/ Acknowledge tone it will commence transmission of the next
message. The ET8 should continue to do this until all alarm messages are
transmitted and Kissed-off.
ACKNOWLEDGE TONE
The person receiving the call can then acknowledge the alarm by pressing the
key on their telephone. Press the key for at least 2 seconds during
pauses in the audible message.
If the alarm is not acknowledged, the keypad’s LINE light will flash continuously
until the panel is next Armed.
ALARM EVENTS SENT
The Reporting Format Table identifies the alarm events which can be
programmed to be sent in Audible Format.
Open/Close reports, Restorals and Exclusions (Isolates) are NOT sent in
Audible Format, even if selected ON.
CENTRAL STATION MONITORING
The ET8 control panel has an on-board digital dialler which can send detailed
alarm messages to a Central Monitoring Station.
The digital messages can include information about the zone/s which caused
the alarm, tamper alarms, low battery or mains failure reports, and it can also
(by user number) identify the users who Arm and Disarm the system.
Central Station Monitoring is highly recommended and is the most effective
method of monitoring your ET8 alarm system.
Installers are welcome to contact E-Tech for further information about
monitoring.
MONITORED PREMISES
CENTRAL STATION MONITORING
TELEPHONE LINE MONITORING STATION
AUDIBLE MONITORING
REPORTING FORMAT TABLE
DIGIT
A
DIGIT
B
1-
2-
3-
4-
5-
6-
7-
8-
21
22
23
24
25
26
2
7
31
32
33
34
35
36
41
42
ALARM
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Duress
Keyswitch Tamper/Panic
Keypad Panic
Radio Panic
Medical alarm
Fire alarm
Exit from installer program mode
External Tamper
Internal Panel Tamper
Keypad Tamper
Radio Tamper
Mains Fail
Panel Battery Fail
RADIO Battery Fail
RADIO Supervision Fail
MONITORED PREMISES
AUDIBLE MONITORING
TELEPHONE LINE MOBILE TELEPHONE
FIXED TELEPHONE